An AHT Cooling Systems refrigerator is perfect for grocery stores, convenience stores and cafeterias; thanks to their reach-in design, they make food selection easy for the consumer. Since these units are important for your business, it’s vital that you take care of them with regular cleanings. If you’re unsure of how to properly clean your AHT Cooling Systems refrigerator, take a look through our step-by-step guide.
This guide is applicable for model series like Ibiza, Malta, Manhattan, Miami, Paris and Sydney.
General Cleaning Steps
- Step 1—Clean the exterior walls and frame.
- Step 2—If equipped, clean the water protection strips and bumpers.
- Step 3—Clean the exterior glass surfaces.
- Step 4—Remove any food residue like packaging debris or spilled liquids.
- Step 5—Clean the lid tracks.
- Step 6—Thoroughly dry all surfaces once they’ve been cleaned.
- Step 7—Clean the floor around the unit.
Bi-Annual Cleaning
For these cleaning steps, the unit must be switched off and in manual defrost.
- Step 1—Move all food products to another unit prior to cleaning.
- Step 2—Press the “[STANDBY RESET]” button for at least 3 seconds until “---” is shown.
- Step 3—Remove all glass lids and their plastic bezels, frames and seals. Thoroughly clean these parts before re-installing them.
- Step 4—Remove all accessories like air ducts and goods grilles from the inside of the unit. Clean all components before re-installing. While cleaning, let all ice and frost on the inner tank walls melt.
- Step 5—Remove the defrost water by following one of the two methods listed below:
- Option 1—Use a wet vacuum to remove the defrost water.
- Option 2—If equipped, use your unit’s defrost water plug. Place a pan under the drain, then remove the plug. Let all the water drain completely before closing the drain.
- Step 6—Remove any food residue like packaging debris or spilled liquids.
- Step 7—Clean the inside of the unit, including the defrost drain and the defrost water sieve.
- Step 8—Clean the airflow channel if needed. To do so, lift up the air-flow channel and clean the areas below carefully with a damp cloth.
- Step 9—Thoroughly dry all surfaces and components.
- Step 10—Reinstall all components, accessories and lids.
- Step 11—Press the “[STANDBY RESET]” button for at least 3 seconds until the temperature is shown.