Antunes Vertical Contact Toaster Error Codes

Antunes Logo - Antunes VCT Toaster Error Codes

An Antunes vertical contact toaster (VCT) is an essential piece of equipment in your commercial kitchen. That’s why it’s so important to fix any issue that arises if you see an error or fault code pop up. Find out what each code means and get a solution quickly with the guide below.

This guide is applicable for the VCT-2000 model.

Fault Codes & Causes

Err 1

  • Cause—Control board failure
  • Solution—Call an authorized service technician

Err 2

  • Cause—Control board failure
  • Solution—Call an authorized service technician

Err 3

  • Cause—Programming DIP switches weren’t adjusted properly when universal control board was installed
  • Solution—Have the DIP switches programmed to match your specific MFG. # settings

Err 4

  • Cause—Platen thermocouple has shorted out
  • Solution—Call an authorized service technician

Err 5

  • Cause—Platen thermocouple is loose, disconnected or open
  • Solution—Call an authorized service technician

Err 6

  • Cause—Control board failure
  • Solution—Call an authorized service technician

Err 7

  • Cause—Control board failure
  • Solution—Call an authorized service technician

Err 8

  • Cause—Control board failure
  • Solution—Call an authorized service technician

Err 9

  • Causes
    • Programming DIP switches weren’t adjusted properly when universal control board was installed
    • If programming DIP switches were adjusted correctly, then the AC isolator board and its wiring is faulty
  • Solution—Have the DIP switches checked by an authorized service agent

Err 10

  • Cause—Control board failure
  • Solution—Call an authorized service technician

CHEC

  • Cause—Ambient temperature in electrical compartment has exceeded 140° F/60° C
  • Solution—Check for proper airflow to electrical component and call an authorized service technician if needed

HI

  • Causes
    • Platen thermocouple is disconnected or open
    • Platen thermocouple’s temperature has exceeded 620° F/327° C
    • Auxiliary heating temperature has exceeded 420 F/215 C and will display “HI” and “USE”
  • Solutions
    • Have the platen thermocouple reconnected or replaced
    • Let the toaster cool down completely if you see “HI” or “HI” and “USE”, then turn off the unit and turn it back on to restart. If this doesn’t solve the issue, contact an authorized service agent.

PO

  • Cause—Incoming power has dropped below 175 volts and causes the unit to shut down
  • Solution—Turn the unit off then back on again. If the issue persists, contact an authorized service agent.

PH

  • Cause—The A/C isolator board is defective or there is loose wiring between the AC isolator board and phase control
  • Solution—Turn the unit off then back on again. If the issue persists, contact an authorized service agent.

For more helpful information about your unit or cleaning instructions, be sure to check out our extensive selection of Antunes manuals and diagrams. 

Please contact a local authorized service agent who can help with these specific units and all your commercial kitchen equipment needs.