If you clocked on this morning only to discover that your company’s ice cream machine is not freezing, turning on or plain not working, we have some Electro Freeze ice cream machine troubleshooting tips for popular models like 30T-RMT, CS700237, 360 ice cream machines and more to help put the twist back into your cones.
Electro Freeze Ice Cream Maker Isn’t Working
Problem
Solution
The freezer is unplugged
Plug in the freezer
There’s a blown fuse or the breaker tripped at the main disconnect
Make sure the freezer is connected to its own circuit that is not shared with any other electrical equipment
If problem persists, please contact an authorized service technician
The actuator rod was not installed
Install the actuator rod
Off on high pressure cut-out or low pressure cut-out control
The water is off or the water
The circuit breaker tripped
Please contact an authorized service technician
The selector switch is faulty
Please contact an authorized service technician
There is a disconnected or broken wire in the electrical circuit
Please contact an authorized service technician
The beater motor is overloaded
Wait for motor to cool down
Press the overload reset button
Reset the circuit breaker
Check the product temperature and consistency
There is a component failure
Please contact an authorized service technician
Mix is Leaking at the Dispensing Head
Problem
Solution
The o-ring is faulty
Replace the o-ring
The head is improperly installed
Install head
Mix or Water is Leaking from Drain Tube to Drip Tray
Problem
Solution
The beater shaft seal is faulty or installed improperly
Replace the cup seals on the washer
Reinstall the beater shaft seal correctly
There is pitting or damage on the beater shaft where the o-ring is located
Replace the beater shaft
The beater shaft’s end play is not set correctly
Please contact an authorized service technician
Product is too Cold/Hard
Problem
Issue
There is low overrun
Check the overrun. If it’s low, please continue to the MTS troubleshooting chart
The plunger is not closed all the way
Close the plunger
The torque control is set incorrectly
Please contact an authorized service technician
The starter or relay control points are stuck
Please contact an authorized service technician
The cylinder thermostat is faulty or set too low
Please contact an authorized service technician
If the unit runs all the time, then the spigot switch is electrically or mechanically stuck in the closed position.
Please contact an authorized service technician
The spigot is not seated correctly in the head
Push the spigot down all the way
The spigot switch rod is engaged
Close the spigot
There is a component failure
Please contact an authorized service technician
The suction pressure is too low in the refrigeration system
Please contact an authorized service technician
The time delay is faulty
Please contact an authorized service technician
Product Dispenses too Slowly
Problem
Solution
The condenser is dirty or blocked or there is high ambient temperature
Clean or unblock the condenser
Lower the ambient temperature
The thermostat’s cut-in point is uncalibrated
Please contact an authorized service technician
The condenser fan motor is faulty
Please contact an authorized service technician
There is a faulty component or compressor
Please contact an authorized service technician
There is low overrun
Check the air meter for blockages
The product is too cold
Check product temperature (18℉)
The beater is rotating the wrong way
Please contact an authorized service technician
The MTS pressure is too low
Please see MTS troubleshooting chart
Electro Freeze Ice Cream Machine Not Freezing
Problem
Issue
The condenser is dirty or blocked
Clean or unblock the condenser
There is a component failure
Please contact an authorized service technician
There is a leak in the refrigeration system
Please contact an authorized service technician
The air filter is dirty
Clean the air filter
The torque control is set incorrectly
Please contact an authorized service technician
Compressor and Beater Motor only Work when Dispensing
Problem
Solution
The cylinder thermostat is set too high or is faulty
Please contact an authorized service technician
Compressor and Beater Motor do not Work
Problem
Solution
The plunger switch is misaligned or faulty
Please contact an authorized service technician
The time delay is faulty
Please contact an authorized service technician
The torque control is faulty
Please contact an authorized service technician
The compressor or the compressor condensing circuit is incorrectly wired
Please contact an authorized service technician
There is low line voltage
Please contact an authorized service technician
There is an open start capacitor, run capacitor or relay (single phase only)
Please contact an authorized service technician
The compressor is faulty
Please contact an authorized service technician
The contactor is faulty
Please contact an authorized service technician
There is a faulty component
Please contact an authorized service technician
There is a faulty wiring in the switch or capacitor relay box
Please contact an authorized service technician
The head assembly is not installed
Please contact an authorized service technician
The magnetic head switch is faulty
Please contact an authorized service technician
The spigot switches are faulty or misaligned
Please contact an authorized service technician
Electro Freeze Ice Cream Machine too Loud
Problem
Solution
The tubing is rattling
Bend the tubes so they are not touching anything
The motor is not seated correctly on internal springs or the springs are bent/broken
Please contact an authorized service technician
Mix Sours While in Cabinet
Problem
Solution
The thermostat is faulty, set too high or is not on
Lower temperature
Turn on thermostat
Contact an authorized service technician
The solenoid valve is faulty
Please contact an authorized service technician
The cabinet switch is faulty
Please contact an authorized service technician
The door switch is faulty
Please contact an authorized service technician
The cabinet compressor contactor coil is in the open position (only if mix sours in night mode)
Please contact an authorized service technician
The time delay is faulty
Please contact an authorized service technician
The suction pressure is too low
Please contact an authorized service technician
MTS Troubleshooting
Problem
Cause
Solution
Mix leaks out of MTS
Transfer hose needs to be replaced
Replace transfer hose
Mix transfer system does not work
The pump cover was not installed
The hose was not installed correctly
The slide switch is faulty
The MTS relay is faulty
The start capacitor or motor start switch is faulty
The pressure switch is faulty
The motor is faulty or the internal overload was tripped
Install the cover
Reinstall the hose
Please contact an authorized service technician
Please contact an authorized service technician
Please contact an authorized service technician
Please contact an authorized service technician
Please contact an authorized service technician
MTS will not turn off
The hose is worn or broken
The pressure switch is stuck closed
Replace the hose
Please contact an authorized service technician
MTS cycles on and off without dispensing
Transfer hose is worn or broken
There is a leak on the pressure side of the system
Replace the hose
Please contact an authorized service technician
MTS will not prime
The mix supply is low
The wing clamp knob is loose
The air hose or air meter are not installed
The hose is not installed
Add more mix
Tighten the knob
Install the air hose or meter
Install the hose
MTS pickup tube loses prime
The duckbill valve is missing or faulty
The inlet clamp is loose
The transfer hose is worn or broken
Replace the duckbill valve
Tighten the clamp
Replace the transfer hose
No air (overrun)
The air meter is clogged
The air tube is pinched
Clean or replace the air meter
Unpinch or replace the tube
Too much air, overrun too high
The air meter is too big
There is an air leak between the pickup tube and hose
The air line hose is worn or broken
The duckbill valve is missing or broken
Replace with a smaller air meter
Ensure hose is connected properly or replace the hose
Replace the air line hose
Replace the duckbill valve
Mix shoots out air meter
The swing clamp knob is too loose
The transfer hose is worn or broken
The MTS pressure is too high
Tighten the knob
Replace the hose
Please contact an authorized service technician
For more preventative maintenance and troubleshooting tips, check out our extensive library of Electro Freeze manuals and diagrams for assistance.
Please contact a local authorized service agent who can help with this specific unit and all your commercial equipment needs.