Multiplex N2Mobile Dispenser Troubleshooting

Multiplex N2Mobile Dispenser Troubleshooting Photo

Make sure everyone can start their day off right with a fresh cup of nitro-infused coffee. Don’t let anyone miss their morning caffeine with our Multiplex N2Mobile dispenser troubleshooting guide below. We will help you through dispensing and refrigerator cabinet issues so you can get your dispenser running like new again. 

Dispensing Issues

Problem

Cause

Solution

Coffee not dispensing

  • Product line not primed
  • Product keg empty
  • Keg connectors not connected
  • Low nitrogen pressure/No nitrogen pressure
  • Nitrogen supply tank empty
  • Nozzle clogged
  • In-line strainer/filter clogged
  • Flow compensator, infuser or check valve clogged
  • Open both plain and nitrogen taps and let flow to prime lines
  • Change out the keg
  • Check the keg connectors
  • Open nitrogen tank valve, adjust pressure, or change nitrogen supply tank
  • Change out nitrogen supply tank
  • Remove and clean nozzle
  • Clean filter
  • Contact an authorized service technician

Coffee is watery

  • Coffee not prepared correctly
  • Change product keg with keg of correctly prepared coffee

Product flowing slowly from valve

  • Nozzle clogged with debris
  • Filter clogged with debris
  • Nitro pressure gauge set incorrectly
  • Flow compensator closed
  • Remove and clean nozzle
  • Remove and clean filter
  • Make sure pressures set correctly
  • Contact an authorized service technician

Product doesn’t look nitrogenated

  • Nozzle doesn’t have diffuser installed
  • Check if nozzles were reversed. Nozzle with diffuser disc should be on Nitro side of tower

Nitrogen supply tank off

  • Turned off when tank swapped/installed
  • Tank incorrectly shut off during keg change
  • Check nitrogen tank
  • Check nitrogen tank

Hissing sound coming from nitrogen tank

  • Regulator nut leaking
  • Tighten regulator nut or check for missing washer inside regulator nut

Puddle of product on floor

  • Bottom catch pan missing
  • Bottom catch pan full
  • Missing or damaged o-rings
  • Find catch pan and replace
  • Empty and clean catch pan
  • Install or replace o-rings as needed

Drip pan under taps has standing coffee

  • Drip pan full
  • Empty and clean drip pan

Foam dispensing from valve

  • Cold brew temp above 45 degrees
  • In-line strainer/filter clogged with debris
  • Attach keg of cold brew chilled to below 45°F
  • Clean filter

Keg connectors won’t go onto keg posts

  • Incorrect connector
  • Not pulling up on connector release ring while connecting
  • Make sure IN connector is gray and OUT connector is black
  • Pull up on ring around connector to allow it to slip over IN or OUT post and lock into place

Refrigerator Cabinet Issues

Problem

Cause

Solution

Warm drinks

  • Ice packs not frozen
  • Too much warm product in cabinet
  • Prolonged door openings or doors ajar
  • Cabinet door not closing
  • Door gasket torn or damaged
  • Replace ice packs and replace warm product keg with chilled product keg
  • Replace warm product keg with chilled product keg
  • Check doors are closed when not in use
  • Check door gasket clean, not damaged and installed correctly
  • Replace door gasket

Leaking internally

  • Check in-line filter bowl and o-ring
  • Missing or damaged o-rings
  • Depressurize unit and remove filter bowl to check
  • Install or replace o-rings as needed