Beverage-Air Undercounter Refrigerator & Freezer Condenser Coil Cleaning
Refrigeration equipment can only run efficiently if proper preventative maintenance is performed on a regular basis. While there are the standard interior and exterior cleaning tasks that need to be done, it doesn’t end there. If you want to ensure your unit stays running, you’ll also have to clean the condenser coil on your Beverage-Air undercounter refrigeration unit.
The following guide is applicable to undercounter refrigerator or freezer models.
Supplies
- Drill or screwdriver
- Vacuum
- Brush
Condenser Cleaning
It’s recommended by Beverage-Air to check on the condenser coil at least monthly and to clean it as needed. You can find the condenser at the back of the unit.
- Step 1. Power down equipment - At the controller, turn off the unit.
- Step 2. Access the condenser - Unscrew the screws at the top of the back panel to gain access to the coil.
- Step 3. Clean up debris - Use a vacuum to remove dust buildup from the condenser.
- Step 4. Clean condenser - Brush up and down to remove any grease or grime.
- Step 5. Fix and inspect the coil - Adjust bent coil fins and check for any damages.
- Note: Contact an authorized service technician if the condenser is damaged.
- Step 6. Reassemble - Reinstall the back panel on the unit.
Need some more guides for commercial refrigeration? Check out our large selection of Beverage-Air manuals and diagrams for tips specific to your model.