From burnt product to a unit that isn’t heating, this simply won’t do when you need to toast bread for sandwiches and burgers. Get a fast fix to help resolve all issues you might face with commercial toasters. This guide has the commercial vertical contact toaster troubleshooting tips you need to get your unit running again in time for breakfast, lunch and dinner service.
Not Working or Heating
- Power cord is unplugged - Plug in the unit.
- Unit is turned off - Turn on the unit.
- Unit is still preheating - Wait for the unit to finish preheating.
- Circuit breaker is off or tripped - Turn on or reset the breaker.
- Heating element is damaged - Contact an authorized service technician.
- Power cord is damaged - Contact an authorized service technician.
- Tripped high limit - Reset the high limit.
- Note: If the high limit continues to trip, contact an authorized service technician.
Conveyor Not Turning
- Motor is faulty - Contact an authorized service technician.
- Conveyor belt is loose, worn or damaged - Contact an authorized service technician.
- Product or debris is jamming the conveyor - Clear away product and debris. Clean the unit if it’s dirty and causing the conveyor to jam.
Product Over or Under Toasted
- Toast settings aren’t properly set - Adjust the toast settings by increasing or decreasing the darkness.
- Bun thickness isn’t set properly - Adjust the bun thickness.
- Wrong program selected - Cancel current program and select a new one. Or, edit the program if needed.
Product Gets Stuck
- Release sheet is dirty - Clean or replace the release sheet.
- Bun thickness isn’t set properly - Adjust the bun thickness.
- Motor is faulty - Contact an authorized service technician.
- Conveyor belt is loose, worn or damaged - Contact an authorized service technician.