Rational Combi Oven Error Codes

Guide
Share
How to Use a Rational Commercial Oven

The Rational Self Cooking Center not only makes cooking easy, but it also has some helpful features for technicians who service the equipment. Perhaps one of the best features is the machine's ability to offer diagnostic codes. Each code will tell you what's wrong with the oven, allowing you to tackle the issue quicker. Below are lists of certain Rational SCC service codes along with their potential causes and remedies.

Service Codes – SCC whitefficiency

Service Code

Cause

Solution

Service 10

SC pump has high water level

 Drain SC pump hose

Service 11

CDS sensor sending too many pulses

Check for leaking in the level electrode and water path to the steam generator

Service 12

CDS sensor without signal

Check if the CDS sensor's signal is blocked of there is low water pressure

Service 13

Steam generator isn't refilled during steam mode

Check the level electrode's 0-1 signal to the PCB

Service 14

Level electrode isn't recognizing water

Water conductivity is too low and needs reverse osmosis treatment

Service 17

SD card not initialized

Clean the existing SD card or use a new one

Service 18

Defective SD card

Use a new SD card

Service 19.1

SD card not inserted

Insert the SD card

Service 20.x

Defective thermocouple:

  • 20.1: Cabinet B1 thermocouple
  • 20.2: Quenching B2 thermocouple
  • 20.4: Humidity B4 thermocouple
  • 20.8: Steam generator B5 thermocouple

COMBINATION OF FAULTY PROBES CAN DISPLAY

Replace thermocouple

Service 23

What's the cause? SSR steam short circuit

Repair or replace

Service 24

SSR hot air short circuit

Repair or replace

Service 25

Improper water flow during CleanJet

Check the water pressure, water supply, moistening valve and nozzle and CDS sensor

Service 26

Permanently closed drain valve

Replace the drain valve assembly

Service 27

Drain valve won't close during initialization

Start the rinse/abort program

Service 28

Thermocouple steam generator B5 temperature is above 356 degrees F (180 degrees C)

Indicator will go off when temperature goes below 230 degrees F (110 degrees C)

Service 29

PCB temperature is above 185 degrees F (85 degrees C)

Check the air filter, cooling fan and control panel gasket as well as external heat sources and air escape openings

Service 30

Unit runs in emergency humidity control

Humidity control is out of function and needs to be repaired or replaced

Service 31.x

Faulty core probe:

  • 31.1: Shaft probe
  • 31.2: Fifth probe (near shaft)
  • 31.4: Fourth probe
  • 31.8: Third probe
  • 31.16: Second probe
  • 31.32: First probe in tip 

COMBINATION OF FAULTY PROBES CAN DISPLAY

Repair or replace the faulty probe

Service 32.0-1-2

Faulty ignition box:

  • 32.0: Ignition box top
  • 32.1: Ignition box bottom (floor models only)
  • 32.2: Both ignition boxes

Change the ignition box that appears in error code

Service 33.1-2

Faulty ignition box:

  • 31.1: Ignition box bottom (floor models only)
  • 31.2: Both ignition boxes

Check the ignition wiring or ignition box gas valve and supply

Service 34.xx

Bus signal problems:

  • 34.1: Motor top
  • 34.2: Motor bottom
  • 34.4: Ignition module top
  • 34.8: Ignition module bottom

COMBINATION OF BUS SIGNAL PROBLEMS CAN DISPLAY

See if the bus cable plug and cable connection are connected or damaged

Service 35

Bus signal can't be processed due to disconnected ultravent

Connect the ultravent

Service 36

Defective differential pressure sensor P1

Repair or replace the sensor

Service 37

Differential pressure sensor P1 isn't in expected range

Check the connection of hoses

Service 40

Care pump is broken or doesn't fill enough solution into the steam generator

Check if the hose from the care pump outlet isn't kinked and reset error by completed a successful rinse program

Service 41

Defective solenoid valve Y3, blocked moistening valve or CDS isn't sending pulses

Resolve issue and reset error by completed a successful rinse program

Service 42

Defective solenoid Y4 Care, hose to Care container blocked/kinked or CDS isn't sending pulses

Resolve issue and reset error by completed a successful rinse program

Service 43

Solenoid Y1, Y3 or Y4 is passing water/won't close and CDS is always sending pulses

Reset error by completed an abort program

Service 44

Steam not heating during CleanJet+Care

Reset error by completed an abort program

Service 60

Incorrect initialization of ignition box?

Check the gas settings and switch the unit off and on again before running the SD Repair program?

Service 63

Self-test running without water

Allow the unit to cool down and see if? B1, B2 and B4 are below 104?F (40?C); Set Selftest to ON and switch unit off and on again before running Selftest

Service 100

Defective SC pump or calcified level electrode

Reset error by completed an abort program

Service 120

Defective Care pump M12 or level electrode

Reset error by completed an abort program

Failure Codes – SCC Line Combi Master (04-2004)

Error Code

Issue

Reason

OPEn / H2o

H2O is open

Lack of water or an open water tap

PoL / CHnG

Polarity change

Phase / neutral (gas units only)

E1

External EEPROM

Not initialized

E2

Timeout of external power optimizing system

Heating block by the external energy-optimizing system is longer than two minutes

E3

B1 interior cabinet sensor

Sensor is broken

E4

B2 quenching sensor

Sensor is broken

E5

B3 core sensor

Sensor is broken

E6

B5 sensor steam generator

Sensor is broken

E7

Thermocouple on PCB

Sensor is broken

E8

Poti interior cabinet

Defective

E9

Poti timer/core temperature

Defective

E10

External EEPROM

Defective

E11

Mode switch

Cooking mode couldn't be identified five seconds after the unit was switched on

E12 / 1 St

Bottom fan motor issue

Motor is defective 

E12?/ 1 Co

Bottom fan motor issue

Bus failure

E12?/ 2 St

Top fan motor issue

Motor is defective

E12?/ 2 Co

Top fan motor issue

Bus failure

E13

M4 SC pump

Malfunction

E14

Solenoid valve filling Y1

Malfunction

E15

PCB temperature

Above 185 degrees F (85 degrees C)

E16

Steam generator

B5 temperature above 356 degrees F (180 degrees C)

E17

Steam generator

B5 temperature below 23 degrees F (-5 degrees C)

E18

Interior cabinet temperature

B1 temperature above 644 degrees F (340 degrees C)

E20 / 1_

Ignition box 1

Ignition box isn't replying due to bus failure

E21 / 2_

Ignition box 2

Ignition box isn't replying due to bus failure

E21 / 1xx

Ignition box 1 steam

Defective ignition box

E22 / 2xx

Ignition box 1 hot air

Defective ignition box

E22 / 3xx

Ignition box 2 hot air

Defective ignition box

E22 / 1xx

Ignition box 1 steam

Testing and monitoring ignition is required

E23 / 2xx

Ignition box 1 hot air

Testing and monitoring ignition is required

E23 / 3xx

Ignition box 2 hot air

Testing and monitoring ignition is required

E24

EEPROM

EEPROM's data structure doesn't match with software

For more information on Rational appliances, check out our selection of manuals and diagrams.

Please contact a local authorized service agent who can help with these specific units and all your commercial kitchen equipment needs.