Pitco Pasta Cooker Error Codes

Pitco pasta cookers are known for their high-volume capacity and high-efficiency operation, making them a popular choice in commercial foodservice kitchens. While performance issues are uncommon, these units display error codes to alert operators and technicians when a problem is detected. If you want to better understand what these fault codes mean, this guide to Pitco pasta cooker error codes explains their possible causes and troubleshooting steps to restore proper operation.

These instructions are for all Pitco pasta cooker models.

_ _ F

  • Water temperature is low - Wait for the unit to finish heating up.

Prob

  • Incorrect probe reading - Contact an authorized service technician to address the issue.

Hi

  • Water level is low - Power down the unit and add more water once it’s cooled.
  • Incorrect Probe Reading - Contact an authorized service technician to solve the problem.

Hi drn tUrn OFF

  • Drain valve is open while the unit is on - Power off the unit and close the valve.

If you found this article helpful, be sure to take a look at the large library of Pitco pasta cooker manuals and diagrams on our site for more information on operating, cleaning and troubleshooting your unit.