Antunes Egg Station Error Codes & Troubleshooting

The Antunes Egg Station provides an easy and hassle-free way to cook eggs perfectly. So when an issue arises, you know you have to get it resolved as quickly as you can. Read on below for a troubleshooting guide and error codes list for the Antunes Standard Egg Station and Dual Zone Egg Station.

This troubleshooting and error codes guide is for Egg Station models ES-600ES-602ES-604ES-1200 and ESDZ-1200.

Troubleshooting for Standard & Dual Zone Egg Stations

Antunes Egg Station Isn’t Working and Control Panel Isn’t Lighting Up

Cause

Solution

No to little power

  • Check to make sure power is on and power cord is firmly plugged into the outlet
  •  Check the circuit breaker

Faulty outlet 

Plug cord into different outlet 

Faulty power cord or button 

Please contact an authorized service technician 

Loose power connections

Please contact an authorized service technician 

Antunes Egg Station Not Heating 

Cause

Solution

Loose power connections

Please contact an authorized service technician 

Faulty platen 

Please contact an authorized service technician 

Low voltage 

Please contact an authorized service technician 

Faulty or damaged hi-limit 

Please contact an authorized service technician 

Faulty or damaged thermocouple 

Please contact an authorized service technician 

Faulty or damaged solid state relay 

Please contact an authorized service technician 

Antunes Egg Station Not Cooking Properly 

Cause

Solution

Refrigerated eggs are being used and either TIME 1 (Standard) or “Folded” (Dual Zone) button is pressed

Use TIME 2 (Standard) or “Round” on refrigerated or shelled eggs

Using room temperature eggs with TIME 2 button selected (Standard) “Round” button pressed when cooking folded eggs (Dual Zone)

Use TIME 1 (Standard) or “Folded” (Dual Zone) when using room temperature eggs or folded eggs

Not enough water in the trough 

Fill the trough with water before starting time cycle

Incorrect temperature on cooking surface

Check the cooking surface’s recommended temperature setting in your respective manual

Loose power connections 

Please contact an authorized service technician 

Table or unit isn’t level

Level the unit or table

Eggs Sticking to the Cooking Surface 

Cause

Solution

Dirty cooking surface

Clean the cooking surface

Not enough cooking oil applied to grill 

Refer to your manual for exact measurements

Eggs Sticking to Egg Rings

Cause

Solution

Not enough cooking oil applied to grill 

Refer to your manual for exact measurements

Egg rings are dirty

Clean the egg rings per manufacturer’s instructions

Damaged egg rings

Replace the egg rings

 Eggs Are Leaking 

Cause

Solution

Egg ring is damaged 

Replace ring 

Egg ring is not installed in the egg rack 

Install the egg ring into the egg rack 

Egg ring is not level on the grill surface 

Set egg ring on the grill so it’s flush against it 

Unit isn’t signaling “Bacon” or “Ready” (for Standard Models)

Cause

Solution

Faulty or damaged indicator light or audio signal

Please contact an authorized service technician 

Faulty or damaged control board

Please contact an authorized service technician 

Loose power connections 

Please contact an authorized service technician 

Bacon timer is deactivated 

Enable Bacon timer based on manufacturer recommendations

Green LED Blink Codes for Standard Egg Station

Number of LED Blinks

Cause(s)

Solution

Blinks on and off 1 time, pauses 2 seconds, repeats pattern

Control board EEPROM memory is corrupted

Unit turns off the control signal to Solid State Relay and disables all front lights and buttons. Unit won’t heat up until defaults are reloaded into memory.

Reload defaults by turning unit off, then pressing and holding the TIME 2 button, turn unit on and then release button.

Blinks on and off 2 times, pauses 2 seconds, repeats pattern

Ambient temperature inside control compartment has exceeded 155° F

Check that there’s proper air ventilation around unit and that unit isn’t around a significant heat source. Allow unit to cool so internal ambient temperature drops below 140° F, and unit is turned off and back on again.

Blinks on and off 3 times, pauses for 2 seconds, repeats pattern

Disconnected or open thermocouple

Have thermocouple reconnected or replaced, then turn unit off and back on.

Blinks on and off 4 times, pauses for 2 seconds, repeats pattern

Voltage supply to unit is below 160 VAC or above 265 VAC

Have the supply voltage reset to within the proper limits, and turn the unit off and back on.

Blinks on and off 5 times, pauses for 2 seconds, repeats pattern

Lost signal to 50/60Hz due to an open harness wire or disconnected harness wire on AC Isolator Board OR from AC Isolator Board to the Control Board

Have the Hz signal reapplied, and turn unit back off and on.

Error Codes for Dual Zone Egg Station

Error Code

Error Code Description

Action Needed

1-9

Issue with circuit board

Contact authorized service technician

10

Unit shuts down because board temperature sensor is over 158° F

Contact authorized service technician

11

Rear heat isn’t reaching setpoint temperature within 30 minutes or is too low

Contact authorized service technician

12

Rear heater isn’t working

Contact authorized service technician

13

Rear thermocouple is defective

Contact authorized service technician

14

Rear hi-limit was tripped

Reset rear Hi-Limit Switch

15

Front Solid State Relay is faulty

Contact authorized service technician

16

Front heat isn’t reaching setpoint temperature within 30 minutes, or is too low

Contact authorized service technician

17

Front heater isn’t working

—Check power outlet’s voltage and try plugging it into a different outlet
—Reset both Hi-Limit Switches

18

Front thermocouple is broken or defective

Contact authorized service technician

19

Front heater hi-limit was tripped

Reset front Hi-Limit Switch

20

Rear Solid State Relay is faulty

Contact authorized service technician

21

Over-temperature condition on rear platen

Contact authorized service technician

22

Over temperature condition on front platen

Contact authorized service technician