When machines have errors, it can stop productivity and really cause a problem in commercial kitchens. Luckily, we have the solutions you need to deal with any Antunes tortilla warmer error codes you might run into. From temperature errors to serious control board issues, we go over the most common codes, their problems and the solutions you need to get equipment back up and running. 

The following fixes are applicable to the TW-100.

Error Codes

Error CodeProblemSolution

2 - Zero Cross

Internal control board error

Power off, unplug and wait 30 seconds, then power back on. For further help, contact an authorized service agent
5 - I2C TimeoutControl board hardware failurePower cycle the unit. For further help, contact an authorized service agent

6 - Memory

Memory chip error

Power off, unplug and wait 30 seconds, then power back on. For further help, contact an authorized service agent
9 - Board TemperatureInternal air temperature too high, system powering downCheck for vent blockage and adequate spacing around vents. Be sure the unit has proper space around it. 
101 - Hi-LimitHi-limit is tripped
Wait 10-15 minutes for cool down. Remove hi-limit control cap. Press hi-limit reset. Turn on unit and test. For further help, contact an authorized service agent

105 - Over Temp

Temperature on top platen is 25°F over set temperature

Power off, unplug and wait 30 seconds, then power back on. For further help, contact an authorized service agent

106 - Over Temp

Temperature on bottom platen is 25°F over set temperature

Power off, unplug and wait 30 seconds, then power back on. For further help, contact an authorized service agent

111 - Under Temp

 

Top platen drops 100°F below set point

temperature when in use


Power off, unplug and wait 30 seconds, then power back on. For further help, contact an authorized service agent

112 - Under Temp

 

Bottom platen drops 100°F below set point

temperature when in use


Power off, unplug and wait 30 seconds, then power back on. For further help, contact an authorized service agent


117 - Open Probe On Top Platen


Thermocouple connection open on platen


Contact an authorized service agent


118 - Open Probe On Bottom Platen


Thermocouple connection open on platen


Contact an authorized service agent


135 - Warmup Time

Top platen taking too long to warm up

Power off, unplug and wait 30 seconds, then power back on. For further help, contact an authorized service agent

136 - Warmup Time

Bottom platen taking too long to warm up

Power off, unplug and wait 30 seconds, then power back on. For further help, contact an authorized service agent

129 - Top Platen Solid State Relay

SSR shorted, wiring shorted or control board failed

Contact an authorized service agent to assist

130 - Bottom Platen Solid State Relay

SSR shorted, wiring shorted or control board failed

Contact an authorized service agent to assist

141 - Top Platen Open Heater

SSR open, wiring open, heater failure or control board failed

Contact an authorized service agent to assist

142 - Bottom Platen Open Heater

SSR open, wiring open, heater failure or control board failed

Contact an authorized service agent to assist

For more information about your unit, such as troubleshooting and more, take a look at our selection of Antunes manuals and diagrams.

Please contact a local authorized service agent who can help with these specific units and all your commercial kitchen equipment needs.